CDCP vs CDCS vs CDCE vs ATD: the differences at a glance

By the Workfully data centre hiring team · Last reviewed

Summary

CDCP, CDCS and CDCE are three steps of one EPI design and build track: foundation, specialist and expert, each needing the one before. ATD (Accredited Tier Designer) is a separate Uptime Institute accreditation for licensed engineers who design facilities to its Tier criteria (Uptime Institute, 2026).

Key facts

  • EPI's CDCP is a two-day course ending in a one-hour, 40-question, closed-book exam with a pass mark of 27. (EPI, October 2026)
  • EPI's CDCS is a three-day course with a 90-minute, 60-question exam, and candidates must hold a valid CDCP when they pass it. (EPI, October 2026)
  • EPI's CDCE is a five-day course with two 90-minute exam parts, one of 60 multiple-choice questions and one of 25 open questions. (EPI, October 2026)
  • Uptime Institute's ATD is a 16-hour live remote programme and examination intended for licensed Professional Engineers with a data centre design management role. (Uptime Institute, October 2026)

CDCP, CDCS and CDCE are the three steps of EPI's data centre (data center in US usage) design and build certification track. ATD is a design accreditation from a different body, Uptime Institute, and it is aimed at licensed engineers rather than the wider facilities workforce (Uptime Institute, 2026).

How do CDCP, CDCS, CDCE and ATD compare?

The table puts the four side by side using only what each issuer states on its own programme page.

Credential Issuer and level Course and exam Entry requirement Validity Suits Source
CDCP (Certified Data Centre Professional) EPI, foundation of the design and build track; accredited by EXIN Two days; one-hour exam, 40 multiple-choice questions, closed book, pass mark 27 None specified Three years, then recertification Facilities, IT and site staff who need a shared technical grounding EPI, 2026
CDCS (Certified Data Centre Specialist) EPI, specialist step; accredited by EXIN Three days; 90-minute exam, 60 multiple-choice questions, closed book, pass mark 45 Valid CDCP Three years, then recertification Facilities engineers and site leads who need depth in power, cooling and fire protection EPI, 2026
CDCE (Certified Data Centre Expert) EPI, expert step; accredited by EXIN Five days; two 90-minute closed-book parts, 60 multiple-choice and 25 open questions Valid CDCS Three years, then recertification Project leads who run a facility from design through commissioning to hand-over EPI, 2026
ATD (Accredited Tier Designer) Uptime Institute, individual endorsement 16 hours, live remote and instructor-led, with an examination at the end Aimed at licensed Professional Engineers; some data centre experience needed Not stated on the programme page Engineers-of-record and senior design engineers on Tier projects Uptime Institute, 2026

The "suits" column is a reading of each issuer's stated audience and syllabus for hiring teams, not a requirement set by EPI or Uptime Institute.

What is the difference between CDCP and CDCS?

CDCP is the entry point and has no specific prerequisite. Its syllabus covers the building blocks of a site, from power and cooling to cabling, fire protection, security and monitoring systems such as building management (EPI, 2026).

CDCS goes deeper into the same plant. Its syllabus adds the data centre life cycle, rating levels and redundancy, air and liquid cooling for AI and HPC, contamination control and efficiency metrics such as PUE (EPI, 2026).

Where do CDCE and ATD sit?

CDCE is the top of EPI's design and build track. Its modules follow a project from design preparation and planning through acquisition, construction, fit-out, test and commissioning, hand-over and retirement (EPI, 2026). EPI runs operations credentials, such as CDFOS and CDFOM, in a separate maintenance and operations track (EPI).

ATD is narrower and more technical. It covers Tier concepts, mechanical and electrical infrastructure design, ancillary systems and common design omissions that disqualify a design (Uptime Institute, 2026). It endorses a person, not a building: Uptime Institute describes itself as the sole licensed firm able to certify a facility against Tier I–IV (Uptime Institute).

Which one should a job advert ask for?

Match the credential to the work. A shift engineer gains more from the CDCP or CDCS syllabus than from a design accreditation, while a lead electrical designer on a Tier project is the natural ATD holder. For each hire in turn, see which certifications to ask for when hiring.

Treat any of the four as evidence of a shared vocabulary, then test live-plant or design experience in the interview. Ask for the certificate date too, because EPI certificates lapse after three years without recertification (EPI, 2026).

Hiring certified engineers for a build or a live site? Workfully is an AI-native recruiting partner built around your hiring needs. Senior specialist recruiters deliver the hires your business needs without scaling your recruiting team. Your team interviews and decides (Workfully for data centres).

Frequently asked questions

Do you need CDCP before CDCS?
Yes. EPI requires candidates to hold a valid CDCP certificate at the time they pass the CDCS exam, and a valid CDCS at the time they pass the CDCE exams. CDCP itself has no specific prerequisite, and EPI welcomes people with no data centre background, although it says some facilities experience helps.
Which of the four is a data centre design certification?
ATD is the design credential in the strict sense. Uptime Institute built it for engineers who design facilities to its Tier criteria, and it covers mechanical, electrical and ancillary system design. CDCE also covers the design phases, but as part of a full project life cycle that runs through construction, test, commissioning and hand-over.
Does an ATD let an engineer certify a facility's Tier level?
No. Passing ATD results in an Uptime Institute endorsement of the individual engineer. A Tier certification of a design or a built facility is a separate service, and Uptime Institute describes itself as the sole licensed firm that can award it. Ask ATD holders which Tier projects they designed, not which buildings they certified.
Which certificates have to be renewed?
EPI states that CDCP, CDCS and CDCE certificates are each valid for three years, after which the holder must recertify. When a CV lists one of them, ask for the issue date. Uptime Institute's ATD page does not set out a renewal period, so check the current position with Uptime directly if it matters for the role.

Sources

  1. EPI. Certified Data Centre Professional (CDCP). Published . Accessed . Tier A, primary.
  2. EPI. Certified Data Centre Specialist (CDCS). Published . Accessed . Tier A, primary.
  3. EPI. Certified Data Centre Expert (CDCE). Published . Accessed . Tier A, primary.
  4. EPI. EPI Data Centre Training Framework. Published . Accessed . Tier A, primary.
  5. Uptime Institute. Accredited Tier Designer (ATD). Published . Accessed . Tier A, primary.
  6. Uptime Institute. Tier Classification System. Published . Accessed . Tier A, primary.